When you estimate that enough data have been recorded,
taking into account the value of the Range Achieved, tap
Stop.
NOTE: You may tap on the Log button again and resume
data logging for the same Site ID name (or for a different
name). This will create a new raw data file (G file), which
by default will be the only one to be seen as a static
observation when imported in GNSS Solutions. In the job
file (csv file), this will result in two points collected.
Select Menu, Exit to close the job and quit ProMark Field.
Rover Collecting
Raw Data in Stop &
Go Kinematic
In Stop & Go kinematic, the rover antenna is placed
successively over several points and each time, a static
occupation takes place for a preset time. Raw data are
collected continuously in the background.
Set up the rover as explained in Typical Setups on
page 17.
Turn on the receiver, run ProMark Field and create a job
as explained in Creating a New Job on page 10.
•On the Options menu, select “Stop & Go Kinematic” and
“Post-processing” on the Survey tab, then tap OK.
Think about which initialization method you will be using
at the beginning of the project and take the corresponding
steps:
From Known Point: Go to the known point and place
the rover antenna exactly over this point.
From Bar: Go to the base (fitted with the initializer bar)
and place the rover antenna at the free end of the
initializer bar.
•Tap Menu and select Configuration...
Select “Rover” from the Configuration drop-down list.
•Tap Settings.
•On the GNSS tab, make sure the “Internal” GNSS receiver
is selected. Ignore the Port field.
Tap on the Antenna tab,
Select “Vertical” and enter the antenna height, which in
this case corresponds to the pole or bipod length.
If you are using a fixed-height pole, just enter this height.
if you are using a height-adjustable pole or bipod, read the
graduation on this device, and then enter the read value
in the Antenna Height field.
Select the antenna type used.