45
function and validate the configuration of the base with
this function disabled. When coming back to the settings
of the base, you will then be allowed to change the storage
medium on the Recording tab. Don’t forget to re-enable the
Record raw data for post-processing function afterwards.
•Tap OK to complete the base configuration step. Tap OK
again to let the receiver operate on its own as an RTK base
until the end of the survey.
NOTE: The Log function is greyed (unavailable) when the
receiver is configured as a base.
You may now quit ProMark Field. The receiver will
continue to smoothly operate as an RTK base and
generate RTK corrections although ProMark Field is not
running anymore.
At the end of the survey, go back to the base and simply
turn it off to end your working session.
NOTE: Quitting the RTK base operating mode for a
receiver operated in this mode can be done in two ways:
Either you turn off the data link used (GSM modem or
external UHF radio) or you set up the receiver as a rover.